Gaining purchaser gratification is our firm's intention eternally. We will make wonderful endeavours to build new and top-quality merchandise, satisfy your exclusive needs and provide you with pre-sale, on-sale and after-sale products and services for Swab Antigen Rapid Test, Mycoplasma Pneumonia, Biological Diagnostics, We sincerely hope to determine some satisfactory interactions with you in the in the vicinity of long term. We'll hold you informed of our progress and stay up for building steady small business relations along with you.
CE Certification Ivd Reagents Factory Quotes – 2019-nCoV Ag Test (Latex Chromatography Assay) / Professional Test / Anterior Nasal Swab – INNOVITA Detail:

Product Detail:

Innovita® 2019-nCoV Ag Test is intended for the direct and qualitative detection of SARS-CoV-2 nucleocapsid protein antigen in anterior nasal swabs from individuals who are suspected of COVID-19 by their healthcare provider within the first seven days of the onset of symptoms or for screening of individuals without symptoms or other reasons to suspect COVID-19 infection.
The test results of this kit are for clinical reference only. It is recommended to conduct a comprehensive analysis of the condition based on the patient’s clinical manifestations and other laboratory tests.

Principle:

The kit is a double antibody sandwich immunoassay based test. The test device consists of the specimen zone and the test zone. The specimen zone contains monoclonal antibody against the SARS-CoV-2 N protein and chicken IgY which both labeled with latex microspheres. The test line contains the other monoclonal antibody against SARS-CoV-2 N protein. The control line contains rabbit-anti-chicken IgY antibody.
After the specimen is applied in the specimen well of the device, antigen in the specimen forms an immune complex with the binding reagent in the specimen zone. Then the complex migrates to the test zone. The test line in the test zone contains antibody from a specific pathogen. If the concentration of the specific antigen in the specimen is higher than LoD, it will be captured at the test line (T) and form a red line. In contrast, if the concentration of the specific antigen is lower than LoD, it will not form a red line. The test also contains an internal control system. A red control line (C) should always appear after the test is completed. Absence of a red control line indicates an invalid result.

Composition:

Composition

Amount

IFU

1

Test cassette

1/25

Extraction diluent

1/25

Dropper tip

1/25

Swab

1/25

Test Procedure:

1.Specimen Collection
Take out the swab from the packaging without touching the padding. Carefully insert the cotton swab 1.5 cm into the nostril until slight resistance is noticeable. Do not insert the swab any deeper if you feel strong resistance or pain. Using moderate pressure, turn the swab 4 – 6 times in a circular motion for at least 15 seconds along the inner nasal wall in order to collect as many cells and mucus as possible. Repeat the sampling with the same swab in the other nostril.

Anterior Nasal Swab (3)

2.Specimen Handling

Anterior Nasal Swab (2)

3.Test Procedure

Anterior Nasal Swab (4)

 

 

● Allow test device, specimen and diluent to equilibrate to room temperature 15~30℃ prior to opening the pouch. Remove the test device from the sealed aluminum foil pouch.
● Apply 3 drops of the test specimen into the specimen well.
● Wait for the red line(s) to appear at room temperature. Read results between 15~30 minutes. Do not read the result after 30 minutes.

 

Results Interpretation:

Anterior Nasal Swab (1)


Product detail pictures:

CE Certification Ivd Reagents Factory Quotes –  2019-nCoV Ag Test (Latex Chromatography Assay) / Professional Test / Anterior Nasal Swab  – INNOVITA detail pictures

CE Certification Ivd Reagents Factory Quotes –  2019-nCoV Ag Test (Latex Chromatography Assay) / Professional Test / Anterior Nasal Swab  – INNOVITA detail pictures


Related Product Guide:

Adhering into the basic principle of "quality, assistance, effectiveness and growth", we have attained trusts and praises from domestic and worldwide client for CE Certification Ivd Reagents Factory Quotes – 2019-nCoV Ag Test (Latex Chromatography Assay) / Professional Test / Anterior Nasal Swab – INNOVITA , The product will supply to all over the world, such as: Angola, Miami, New Orleans, Our company has a skillful sales team, strong economic foundation, great technical force, advanced equipment, complete testing means, and excellent after-sales services. Our items have beautiful appearance, fine workmanship and superior quality and win the unanimous approvals of the customers all over the world.
  • This company has the idea of "better quality, lower processing costs, prices are more reasonable", so they have competitive product quality and price, that's the main reason we chose to cooperate.
    5 Stars By Emily from Honduras - 2018.09.16 11:31
    In China, we have purchased many times, this time is the most successful and most satisfactory, a sincere and realiable Chinese manufacturer!
    5 Stars By Griselda from Belgium - 2017.04.08 14:55
    Write your message here and send it to us