With dependable high-quality method, fantastic standing and ideal purchaser assistance, the series of products produced by our firm are exported to many countries and regions for China Rapid Antigen Test Kit, Zika IgG/IgM, Medical Supply, As an experienced group we also accept custom-made orders. The main intention of our firm is to build up a satisfying memory for all consumers, and set up a long-term win-win small business connection.
CE Certification LP Manufacturers Exporters – 2019-nCoV Ag Test (Latex Chromatography Assay) / Professional Test / Saliva – INNOVITA Detail:

Product Detail:

Innovita® 2019-nCoV Ag Test is intended for the direct and qualitative detection of SARS-CoV-2 nucleocapsid protein antigen in saliva from individuals who are suspected of COVID-19 by their healthcare provider within the first seven days of the onset of symptoms or for screening of individuals without symptoms or other reasons to suspect COVID-19 infection.
The test results of this kit are for clinical reference only. It is recommended to conduct a comprehensive analysis of the condition based on the patient’s clinical manifestations and other laboratory tests.

Principle:

The kit is a double antibody sandwich immunoassay based test. The test device consists of the specimen zone and the test zone. The specimen zone contains monoclonal antibody against the SARS-CoV-2 N protein and chicken IgY which both labeled with latex microspheres. The test line contains the other monoclonal antibody against SARS-CoV-2 N protein. The control line contains rabbit-anti-chicken IgY antibody.
After the specimen is applied in the specimen well of the device, antigen in the specimen forms an immune complex with the binding reagent in the specimen zone. Then the complex migrates to the test zone. The test line in the test zone contains antibody from a specific pathogen. If the concentration of the specific antigen in the specimen is higher than LoD, it will be captured at the test line (T) and form a red line. In contrast, if the concentration of the specific antigen is lower than LoD, it will not form a red line. The test also contains an internal control system. A red control line (C) should always appear after the test is completed. Absence of a red control line indicates an invalid result.

Composition:

Composition

Amount

IFU

1

Test cassette

1/20

Extraction diluent

1/20

Saliva collector

1/20

Test Procedure:

1.Specimen Collection and Handling

● Unscrew the cap of the extraction diluent and place the saliva collector on it.
● Rinse mouth with water. Cough deeply three times. Spit out saliva from the posterior oropharynx into the open funnel. Collect saliva through the saliva collector up to the fill line. Do not exceed the fill line.
● Remove the saliva collector and screw the lid of the sample tube back on.
● Shake the test tube 10 times so that the saliva mixes thoroughly with the extraction diluent. Then let stand for 1 minute and shake well again.

* If the saliva sample is visibly cloudy, leave it to settle before testing.Specimen

Professional Test--Saliva (2)

2.Test Procedure

Professional Test--Saliva (3)

● Allow test device, specimen and diluent equilibrate to room temperature 15~30℃ prior to opening the pouch. Remove the test device from the sealed aluminum foil pouch.
● Apply 4-5 drops of the test specimen into the specimen well.
● Wait for the red line(s) to appear at room temperature. Read results between 15~30 minutes. Do not read the result after 30 minutes.

Results Interpretation:

Professional Test--Saliva (1)


Product detail pictures:

CE Certification LP Manufacturers Exporters –  2019-nCoV Ag Test (Latex Chromatography Assay) / Professional Test / Saliva  – INNOVITA detail pictures

CE Certification LP Manufacturers Exporters –  2019-nCoV Ag Test (Latex Chromatography Assay) / Professional Test / Saliva  – INNOVITA detail pictures


Related Product Guide:

We pursue the administration tenet of "Quality is exceptional, Provider is supreme, Name is first", and will sincerely create and share success with all clientele for CE Certification LP Manufacturers Exporters – 2019-nCoV Ag Test (Latex Chromatography Assay) / Professional Test / Saliva – INNOVITA , The product will supply to all over the world, such as: Pakistan, Russia, Kenya, To make every client satisfied with us and achieve win-win success, we will continue to try our best to serve and satisfy you! Sincerely looking forward to cooperating with more overseas customers based on mutual benefits and great future business. Thank you.
  • This is a reputable company, they have a high level of business management, good quality product and service, every cooperation is assured and delighted!
    5 Stars By Elva from Armenia - 2017.04.28 15:45
    A nice supplier in this industry, after a detail and careful discussion, we reached a consensus agreement. Hope that we cooperate smoothly.
    5 Stars By Prima from San Francisco - 2017.11.11 11:41
    Write your message here and send it to us