banner

Products

CE Certification Neutralizing Antibody Rapid Test Kit Manufacturers Exporters – Flu A/Flu B/2019-nCoV Ag 3 in 1 Combo Test – INNOVITA

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Dedicated to strict quality management and thoughtful client services, our experienced staff customers are generally available to discuss your demands and guarantee full client pleasure for Rapid Antigen Test, FOB test, Cardiac Marker, In addition, we would properly guide the customers about the application techniques to adopt our products and the way to select appropriate materials.
CE Certification Neutralizing Antibody Rapid Test Kit Manufacturers Exporters – Flu A/Flu B/2019-nCoV Ag 3 in 1 Combo Test – INNOVITA Detail:

Product Detail:

Innovita® Flu A/Flu B/2019-nCoV Ag 3 in 1 Combo Test is intended for the qualitative detection and differentiation of nucleocapsid antigen from Influenza Virus type A, Influenza Virus type B and 2019-nCoV directly from nasopharyngeal swab specimens obtained from individuals.
It can be only used in professional institutions.
A positive test result requires further confirmation. A negative test result does not rule out the possibility of infection.
The test results of this kit are for clinical reference only. It is recommended to conduct a comprehensive analysis of the condition based on the patient’s clinical manifestations and other laboratory tests.

Principle:

The kit is a double antibody sandwich immunoassay-based test. The test device consists of the specimen zone and the test zone.
1) Flu A/Flu B Ag: The specimen zone contains monoclonal antibody against the Flu A/Flu B N protein. The test line contains the other monoclonal antibody against Flu A/Flu B protein. The control line contains goat-anti-mouse IgG antibody.
2) 2019-nCoV Ag: The specimen zone contains monoclonal antibody against the 2019-nCoV N protein and chicken IgY. The test line contains the other monoclonal antibody against 2019-nCoV N protein. The control line contains rabbit-anti-chicken IgY antibody.
After the specimen is applied in the specimen well of the device, antigen in the specimen forms an immune complex with the binding antibody in the specimen zone. Then the complex migrates to the test zone. The test line in the test zone contains antibody from a specific pathogen. If the concentration of the specific antigen in the specimen is higher than LOD, it will form a purple-red line at the test line (T). In contrast, if the concentration of the specific antigen is lower than LOD, it will not form a purple-red line. The test also contains an internal control system. A purple-red control line (C) should always appear after the test is completed. Absence of a purple-red control line indicates an invalid result.

Composition:

Composition

Amount

Specification

IFU

1

/

Test cassette

25

Each sealed foil pouch containing one test device and one desiccant

Extraction diluent

500μL*1 Tube *25

Tris-Cl buffer, NaCl, NP 40, ProClin 300

Dropper tip

25

/

Swab

25

/

Test Procedure:

1. Specimen collection requirements:
1.Place the swab into one of the patient’s nostrils until it reaches the posterior nasopharynx; keep inserting until resistance is encountered or the distance is equivalent to that from the ear to the nostril of the patient. The swab should be rotated on the nasopharyngeal mucosa for 5 times or more, and then taken out.
2.Freshly collected dry swabs should be processed as soon as possible, but no later than 1 hour after specimen collection.

(Multiple Fluorescence PCR)  (1)
2. Specimen handling:

(Multiple Fluorescence PCR)  (2)
3.Results Interpretation

(Multiple Fluorescence PCR)  (3)


Product detail pictures:

CE Certification Neutralizing Antibody Rapid Test Kit Manufacturers Exporters –  Flu A/Flu B/2019-nCoV Ag 3 in 1 Combo Test  – INNOVITA detail pictures


Related Product Guide:

Sticking for the perception of "Creating goods of high quality and making good friends with people today from all around the world", we constantly set the interest of shoppers to begin with for CE Certification Neutralizing Antibody Rapid Test Kit Manufacturers Exporters – Flu A/Flu B/2019-nCoV Ag 3 in 1 Combo Test – INNOVITA , The product will supply to all over the world, such as: Sacramento, Mongolia, United Arab emirates, When It produced, it making use of the world's major method for reliable operation, a low failure price, it appropriate for Jeddah shoppers choice. Our enterprise. s situated inside the national civilized cities, the website traffic is very hassle-free, unique geographical and financial circumstances. We pursue a "people-oriented, meticulous manufacturing, brainstorm, make brilliant" company philosophy. Strict good quality management, fantastic service, affordable cost in Jeddah is our stand around the premise of competitors. If needed, welcome to make contact with us by our web page or phone consultation, we'll be delighted to serve you.
  • The company comply with the contract strict, a very reputable manufacturers, worthy a long-term cooperation.
    5 Stars By Elaine from Chicago - 2018.12.30 10:21
    We have been engaged in this industry for many years, we appreciate the work attitude and production capacity of the company, this is a reputable and professional manufacturer.
    5 Stars By Roberta from Ethiopia - 2017.11.11 11:41
    Write your message here and send it to us