banner

Products

High-Quality OEM Ab test Factory Quotes – 2019-nCoV Ag Test (Latex Chromatography Assay) / Professional Test / Anterior Nasal Swab – INNOVITA

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Good quality comes initial; company is foremost; small business is cooperation" is our business philosophy which is frequently observed and pursued by our business for Antigen Test Cassette, Rapid Test PCR, Rubella, We persistently develop our enterprise spirit "quality lives the business, credit score assures cooperation and retain the motto inside our minds: consumers very first.
High-Quality OEM Ab test Factory Quotes – 2019-nCoV Ag Test (Latex Chromatography Assay) / Professional Test / Anterior Nasal Swab – INNOVITA Detail:

Product Detail:

Innovita® 2019-nCoV Ag Test is intended for the direct and qualitative detection of SARS-CoV-2 nucleocapsid protein antigen in anterior nasal swabs from individuals who are suspected of COVID-19 by their healthcare provider within the first seven days of the onset of symptoms or for screening of individuals without symptoms or other reasons to suspect COVID-19 infection.
The test results of this kit are for clinical reference only. It is recommended to conduct a comprehensive analysis of the condition based on the patient’s clinical manifestations and other laboratory tests.

Principle:

The kit is a double antibody sandwich immunoassay based test. The test device consists of the specimen zone and the test zone. The specimen zone contains monoclonal antibody against the SARS-CoV-2 N protein and chicken IgY which both labeled with latex microspheres. The test line contains the other monoclonal antibody against SARS-CoV-2 N protein. The control line contains rabbit-anti-chicken IgY antibody.
After the specimen is applied in the specimen well of the device, antigen in the specimen forms an immune complex with the binding reagent in the specimen zone. Then the complex migrates to the test zone. The test line in the test zone contains antibody from a specific pathogen. If the concentration of the specific antigen in the specimen is higher than LoD, it will be captured at the test line (T) and form a red line. In contrast, if the concentration of the specific antigen is lower than LoD, it will not form a red line. The test also contains an internal control system. A red control line (C) should always appear after the test is completed. Absence of a red control line indicates an invalid result.

Composition:

Composition

Amount

IFU

1

Test cassette

1/25

Extraction diluent

1/25

Dropper tip

1/25

Swab

1/25

Test Procedure:

1.Specimen Collection
Take out the swab from the packaging without touching the padding. Carefully insert the cotton swab 1.5 cm into the nostril until slight resistance is noticeable. Do not insert the swab any deeper if you feel strong resistance or pain. Using moderate pressure, turn the swab 4 – 6 times in a circular motion for at least 15 seconds along the inner nasal wall in order to collect as many cells and mucus as possible. Repeat the sampling with the same swab in the other nostril.

Anterior Nasal Swab (3)

2.Specimen Handling

Anterior Nasal Swab (2)

3.Test Procedure

Anterior Nasal Swab (4)

 

 

● Allow test device, specimen and diluent to equilibrate to room temperature 15~30℃ prior to opening the pouch. Remove the test device from the sealed aluminum foil pouch.
● Apply 3 drops of the test specimen into the specimen well.
● Wait for the red line(s) to appear at room temperature. Read results between 15~30 minutes. Do not read the result after 30 minutes.

 

Results Interpretation:

Anterior Nasal Swab (1)


Product detail pictures:

High-Quality OEM Ab test Factory Quotes –  2019-nCoV Ag Test (Latex Chromatography Assay) / Professional Test / Anterior Nasal Swab  – INNOVITA detail pictures

High-Quality OEM Ab test Factory Quotes –  2019-nCoV Ag Test (Latex Chromatography Assay) / Professional Test / Anterior Nasal Swab  – INNOVITA detail pictures


Related Product Guide:

Our company has been focusing on brand strategy. Customers' satisfaction is our best advertising. We also supply OEM service for High-Quality OEM Ab test Factory Quotes – 2019-nCoV Ag Test (Latex Chromatography Assay) / Professional Test / Anterior Nasal Swab – INNOVITA , The product will supply to all over the world, such as: Honduras, Las Vegas, Azerbaijan, We have exported our products all over the world, especially the USA and European countries. Furthermore, all of our products are manufactured with advanced equipment and strict QC procedures to ensure high quality.If you are interested in any of our products, please don't hesitate to contact us. We will try our best to meet your needs.
  • Good quality and fast delivery, it's very nice. Some products have a little bit problem, but the supplier replaced timely, overall, we are satisfied.
    5 Stars By Irma from Sudan - 2018.10.01 14:14
    The customer service staff is very patient and has a positive and progressive attitude to our interest, so that we can have a comprehensive understanding of the product and finally we reached an agreement, thanks!
    5 Stars By Mark from Cairo - 2018.09.12 17:18
    Write your message here and send it to us