We pursue the administration tenet of "Quality is remarkable, Services is supreme, Status is first", and will sincerely create and share success with all customers for POCT, Drug test, Malaria Pf/Pv, Safety through innovation is our promise to each other.
High-Quality OEM China Antigen Saliva Rapid Test Factory Quotes – 2019-nCoV Ag Test (Latex Chromatography Assay) / Professional Test / Nasopharyngeal Swab – INNOVITA Detail:

Product Detail:

Innovita® 2019-nCoV Ag Test is intended for the direct and qualitative detection of SARS-CoV-2 nucleocapsid protein antigen in nasopharyngeal swabs from individuals who are suspected of COVID-19 by their healthcare provider within the first seven days of the onset of symptoms or for screening of individuals without symptoms or other reasons to suspect COVID-19 infection.
The test results of this kit are for clinical reference only. It is recommended to conduct a comprehensive analysis of the condition based on the patient’s clinical manifestations and other laboratory tests.

Principle:

The kit is a double antibody sandwich immunoassay based test. The test device consists of the specimen zone and the test zone. The specimen zone contains monoclonal antibody against the SARS-CoV-2 N protein and chicken IgY which both labeled with latex microspheres. The test line contains the other monoclonal antibody against SARS-CoV-2 N protein. The control line contains rabbit-anti-chicken IgY antibody.
After the specimen is applied in the specimen well of the device, antigen in the specimen forms an immune complex with the binding reagent in the specimen zone. Then the complex migrates to the test zone. The test line in the test zone contains antibody from a specific pathogen. If the concentration of the specific antigen in the specimen is higher than LoD, it will be captured at the test line (T) and form a red line. In contrast, if the concentration of the specific antigen is lower than LoD, it will not form a red line. The test also contains an internal control system. A red control line (C) should always appear after the test is completed. Absence of a red control line indicates an invalid result.

Composition:

Composition

Amount

IFU

1

Test cassette

1/25

Extraction diluent

1/25

Dropper tip

1/25

Swab

1/25

Test Procedure:

1.Specimen Collection
Place the swab into one of the patient’s nostrils until it reaches the posterior nasopharynx; keep inserting until resistance is encountered or the distance is equivalent to that from the ear to the nostril of the patient. The swab should be rotated on the nasopharyngeal mucosa for 5 times or more, and then taken out.

Nasopharygeal Swab (2)
2.Specimen Handling

Nasopharygeal Swab (4)

3.Test Procedure

Nasopharygeal Swab (1)

● Allow test device, specimen and diluent to equilibrate to room temperature 15~30℃ prior to opening the pouch. Remove the test device from the sealed aluminum foil pouch.
● Apply 3 drops of the test specimen into the specimen well.
● Wait for the red line(s) to appear at room temperature. Read results between 15~30 minutes. Do not read the result after 30 minutes.

Results Interpretation:

Nasopharygeal Swab (3)


Product detail pictures:

High-Quality OEM China Antigen Saliva Rapid Test Factory Quotes –  2019-nCoV Ag Test (Latex Chromatography Assay) / Professional Test / Nasopharyngeal Swab  – INNOVITA detail pictures

High-Quality OEM China Antigen Saliva Rapid Test Factory Quotes –  2019-nCoV Ag Test (Latex Chromatography Assay) / Professional Test / Nasopharyngeal Swab  – INNOVITA detail pictures


Related Product Guide:

With this motto in mind, we have become one of the most technologically innovative, cost-efficient, and price-competitive manufacturers for High-Quality OEM China Antigen Saliva Rapid Test Factory Quotes – 2019-nCoV Ag Test (Latex Chromatography Assay) / Professional Test / Nasopharyngeal Swab – INNOVITA , The product will supply to all over the world, such as: Barcelona, Malawi, Rotterdam, As a way to use the resource on the expanding info in international trade, we welcome prospects from everywhere on the web and offline. In spite on the high quality items we offer, effective and satisfying consultation service is supplied by our qualified after-sale service group. Item lists and detailed parameters and any other info weil be sent to you timely for the inquiries. So please make contact with us by sending us emails or call us when you've got any questions about our organization. ou could also get our address information from our site and come to our enterprise. We get a field survey of our merchandise. We are confident that we'll share mutual accomplishment and create solid co-operation relations with our companions within this market place. We're seeking forward for your inquiries.
  • The company account manager has a wealth of industry knowledge and experience, he could provide appropriate program according our needs and speak English fluently.
    5 Stars By Madeline from Bangkok - 2018.06.18 19:26
    We have worked with many companies, but this time is the best,detailed explanation, timely delivery and quality qualified, nice!
    5 Stars By Bruno Cabrera from Colombia - 2018.11.04 10:32
    Write your message here and send it to us