High-Quality OEM In Vitro Diagnostic Test Factories Pricelist – Flu A/Flu B/2019-nCoV Ag 3 in 1 Combo Test – INNOVITA
High-Quality OEM In Vitro Diagnostic Test Factories Pricelist – Flu A/Flu B/2019-nCoV Ag 3 in 1 Combo Test – INNOVITA Detail:
Product Detail:
Innovita® Flu A/Flu B/2019-nCoV Ag 3 in 1 Combo Test is intended for the qualitative detection and differentiation of nucleocapsid antigen from Influenza Virus type A, Influenza Virus type B and 2019-nCoV directly from nasopharyngeal swab specimens obtained from individuals.
It can be only used in professional institutions.
A positive test result requires further confirmation. A negative test result does not rule out the possibility of infection.
The test results of this kit are for clinical reference only. It is recommended to conduct a comprehensive analysis of the condition based on the patient’s clinical manifestations and other laboratory tests.
Principle:
The kit is a double antibody sandwich immunoassay-based test. The test device consists of the specimen zone and the test zone.
1) Flu A/Flu B Ag: The specimen zone contains monoclonal antibody against the Flu A/Flu B N protein. The test line contains the other monoclonal antibody against Flu A/Flu B protein. The control line contains goat-anti-mouse IgG antibody.
2) 2019-nCoV Ag: The specimen zone contains monoclonal antibody against the 2019-nCoV N protein and chicken IgY. The test line contains the other monoclonal antibody against 2019-nCoV N protein. The control line contains rabbit-anti-chicken IgY antibody.
After the specimen is applied in the specimen well of the device, antigen in the specimen forms an immune complex with the binding antibody in the specimen zone. Then the complex migrates to the test zone. The test line in the test zone contains antibody from a specific pathogen. If the concentration of the specific antigen in the specimen is higher than LOD, it will form a purple-red line at the test line (T). In contrast, if the concentration of the specific antigen is lower than LOD, it will not form a purple-red line. The test also contains an internal control system. A purple-red control line (C) should always appear after the test is completed. Absence of a purple-red control line indicates an invalid result.
Composition:
Composition |
Amount |
Specification |
IFU |
1 |
/ |
Test cassette |
25 |
Each sealed foil pouch containing one test device and one desiccant |
Extraction diluent |
500μL*1 Tube *25 |
Tris-Cl buffer, NaCl, NP 40, ProClin 300 |
Dropper tip |
25 |
/ |
Swab |
25 |
/ |
Test Procedure:
1. Specimen collection requirements:
1.Place the swab into one of the patient’s nostrils until it reaches the posterior nasopharynx; keep inserting until resistance is encountered or the distance is equivalent to that from the ear to the nostril of the patient. The swab should be rotated on the nasopharyngeal mucosa for 5 times or more, and then taken out.
2.Freshly collected dry swabs should be processed as soon as possible, but no later than 1 hour after specimen collection.
2. Specimen handling:
3.Results Interpretation
Product detail pictures:
Related Product Guide:
Like a result of ours specialty and repair consciousness, our enterprise has won a superb popularity amid buyers everywhere in the environment for High-Quality OEM In Vitro Diagnostic Test Factories Pricelist – Flu A/Flu B/2019-nCoV Ag 3 in 1 Combo Test – INNOVITA , The product will supply to all over the world, such as: Las Vegas, Belarus, UK, During in 11 years, We have participated in more than 20 exhibitions, obtains the highest praise from each customer. Our company has been devoting that "customer first" and committed to helping customers expand their business, so that they become the Big Boss !
By Norma from French - 2017.04.18 16:45
Speaking of this cooperation with the Chinese manufacturer, I just want to say"well dodne", we are very satisfied.
By Constance from Brunei - 2018.12.25 12:43