banner

Products

High-Quality OEM Quantum Dot Immunofluorescence Chromatography Factory Quotes – 2019-nCoV Ag Test (Latex Chromatography Assay) / Professional Test / Saliva – INNOVITA

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our goal is to satisfy our customers by offering golden service, good price and high quality for Antibody test, Rapid Test Kits, Parainfluenza Virus Type 2, The mission of our company is to provide the highest quality products with best price. We are looking forward to doing business with you!
High-Quality OEM Quantum Dot Immunofluorescence Chromatography Factory Quotes – 2019-nCoV Ag Test (Latex Chromatography Assay) / Professional Test / Saliva – INNOVITA Detail:

Product Detail:

Innovita® 2019-nCoV Ag Test is intended for the direct and qualitative detection of SARS-CoV-2 nucleocapsid protein antigen in saliva from individuals who are suspected of COVID-19 by their healthcare provider within the first seven days of the onset of symptoms or for screening of individuals without symptoms or other reasons to suspect COVID-19 infection.
The test results of this kit are for clinical reference only. It is recommended to conduct a comprehensive analysis of the condition based on the patient’s clinical manifestations and other laboratory tests.

Principle:

The kit is a double antibody sandwich immunoassay based test. The test device consists of the specimen zone and the test zone. The specimen zone contains monoclonal antibody against the SARS-CoV-2 N protein and chicken IgY which both labeled with latex microspheres. The test line contains the other monoclonal antibody against SARS-CoV-2 N protein. The control line contains rabbit-anti-chicken IgY antibody.
After the specimen is applied in the specimen well of the device, antigen in the specimen forms an immune complex with the binding reagent in the specimen zone. Then the complex migrates to the test zone. The test line in the test zone contains antibody from a specific pathogen. If the concentration of the specific antigen in the specimen is higher than LoD, it will be captured at the test line (T) and form a red line. In contrast, if the concentration of the specific antigen is lower than LoD, it will not form a red line. The test also contains an internal control system. A red control line (C) should always appear after the test is completed. Absence of a red control line indicates an invalid result.

Composition:

Composition

Amount

IFU

1

Test cassette

1/20

Extraction diluent

1/20

Saliva collector

1/20

Test Procedure:

1.Specimen Collection and Handling

● Unscrew the cap of the extraction diluent and place the saliva collector on it.
● Rinse mouth with water. Cough deeply three times. Spit out saliva from the posterior oropharynx into the open funnel. Collect saliva through the saliva collector up to the fill line. Do not exceed the fill line.
● Remove the saliva collector and screw the lid of the sample tube back on.
● Shake the test tube 10 times so that the saliva mixes thoroughly with the extraction diluent. Then let stand for 1 minute and shake well again.

* If the saliva sample is visibly cloudy, leave it to settle before testing.Specimen

Professional Test--Saliva (2)

2.Test Procedure

Professional Test--Saliva (3)

● Allow test device, specimen and diluent equilibrate to room temperature 15~30℃ prior to opening the pouch. Remove the test device from the sealed aluminum foil pouch.
● Apply 4-5 drops of the test specimen into the specimen well.
● Wait for the red line(s) to appear at room temperature. Read results between 15~30 minutes. Do not read the result after 30 minutes.

Results Interpretation:

Professional Test--Saliva (1)


Product detail pictures:

High-Quality OEM Quantum Dot Immunofluorescence Chromatography Factory Quotes –  2019-nCoV Ag Test (Latex Chromatography Assay) / Professional Test / Saliva  – INNOVITA detail pictures

High-Quality OEM Quantum Dot Immunofluorescence Chromatography Factory Quotes –  2019-nCoV Ag Test (Latex Chromatography Assay) / Professional Test / Saliva  – INNOVITA detail pictures


Related Product Guide:

We stick to our enterprise spirit of "Quality, Efficiency, Innovation and Integrity". We aim to create more value for our customers with our rich resources, advanced machinery, experienced workers and excellent services for High-Quality OEM Quantum Dot Immunofluorescence Chromatography Factory Quotes – 2019-nCoV Ag Test (Latex Chromatography Assay) / Professional Test / Saliva – INNOVITA , The product will supply to all over the world, such as: Croatia, Swansea, Germany, Our staffs are rich in experience and trained strictly, with qualified knowledge, with energy and always respect their customers as the No. 1, and promise to do their best to deliver the effective and individual service for customers. The Company pays attention to maintaining and developing the long-term cooperation relationship with the customers. We promise, as your ideal partner, we'll develop a bright future and enjoy the satisfying fruit together with you, with persisting zeal, endless energy and forward spirit.
  • Good quality and fast delivery, it's very nice. Some products have a little bit problem, but the supplier replaced timely, overall, we are satisfied.
    5 Stars By Salome from Mozambique - 2017.04.18 16:45
    On this website, product categories is clear and rich, I can find the product I want very quickly and easily, this is really very good!
    5 Stars By Susan from Frankfurt - 2017.07.28 15:46
    Write your message here and send it to us