We always do the job to be a tangible group making sure that we can provide you with the top top quality as well as ideal value for Neutralizing Antibody Rapid Test Kit, Human Parvovirus, Collection Swab, We have now deep cooperation with hundreds of factories all over China. The goods we give can match with your different calls for. Choose us, and we won't make you regret!
High-Quality OEM Rapid Test Device Manufacturers Exporters – Novel Coronavirus (2019-nCoV) Nucleic Acid Test Kit (Multiple Fluorescence PCR) – INNOVITA Detail:

Product Detail:

Innovita® 2019-nCoV IgM/IgG Test is intended for the diagnosis and epidemiological monitoring of diseases caused by the novel coronavirus (2019-nCoV). ORF1ab and N gene of 2019-nCoV are detected qualitatively from throat swabs and alveolar lavage fluid samples collected from suspected cases of pneumonia, patients with suspected cases, others who need to diagnose.
The test results of this kit are for clinical reference only. It is recommended to conduct a comprehensive analysis of the condition based on the patient’s clinical manifestations and other laboratory tests.

Principle:

This kit uses one-step reverse transcription polymerase chain reaction (RT-PCR) detection technology to target the novel coronavirus (2019-nCoV) ORF1ab gene, N gene, and human internal reference gene sequence. Specific primers and taqman probes were designed in conserved regions.

Composition:

Composition

48 tests / kit

Reaction Mix A 792μL×1Tube
Reaction Mix B 168μL×1Tube
Positive Control 50μL×1Tube
Negative Control 50μL ×1Tube

Note: 1. Different batches of reagents should not be mixed.
2. Positive controls and positive controls need not be extracted

Test Procedure:

1. Nucleic acid extraction:
Commercial RNA extraction kits are available, magnetic bead extraction and spin column extraction are recommended for this kit.
2. Preparation the Reaction Mix:

● Take out the 2019-nCoV reaction Mix A/B and keep at room temperature until unfreezing;
● Take the corresponding portions (Reaction Mix A 16.5μL/T, Reaction Mix B 3.5μL/T) and mix, and then aliquot each PCR reaction with 20μL/ tube;
● Add 5μL of RNA template or negative control or positive control, then cover the tube cap;
● Place the reaction tube in the fluorescence PCR instrument, and set the negative / positive control and sample parameters for RT-PCR reaction according to the instrument operating instructions.
● Record Sample placement order

3.RT-PCR protocols:

Recommended Settings:

Cycle

Time

Temperature

1

1

10min

25

2

1

10min

50

3

1

10min

95

4

45

10s

95

35s

55


Product detail pictures:

High-Quality OEM Rapid Test Device Manufacturers Exporters –  Novel Coronavirus (2019-nCoV) Nucleic Acid Test Kit (Multiple Fluorescence PCR)  – INNOVITA detail pictures


Related Product Guide:

We depend on sturdy technical force and continually create sophisticated technologies to meet the demand of High-Quality OEM Rapid Test Device Manufacturers Exporters – Novel Coronavirus (2019-nCoV) Nucleic Acid Test Kit (Multiple Fluorescence PCR) – INNOVITA , The product will supply to all over the world, such as: Atlanta, Malawi, Albania, We also have the strong ability of integration to supply our best service, and plan to build the warehouse in the different countries around the world, that will be more conveniently to service our customers.
  • Hope that the company could stick to the enterprise spirit of "Quality, Efficiency, Innovation and Integrity", it will be better and better in the future.
    5 Stars By Frank from Sri Lanka - 2018.12.10 19:03
    We have been looking for a professional and responsible supplier, and now we find it.
    5 Stars By Edwina from Algeria - 2017.10.25 15:53
    Write your message here and send it to us