Paint Drying Chamber Factory Quotes – Novel Coronavirus (2019-nCoV) Nucleic Acid Test Kit – INNOVITA
Paint Drying Chamber Factory Quotes – Novel Coronavirus (2019-nCoV) Nucleic Acid Test Kit – INNOVITA Detail:
Product Detail:
Innovita® 2019-nCoV IgM/IgG Test is intended for the diagnosis and epidemiological monitoring of diseases caused by the novel coronavirus (2019-nCoV). ORF1ab and N gene of 2019-nCoV are detected qualitatively from throat swabs and alveolar lavage fluid samples collected from suspected cases of pneumonia, patients with suspected cases, others who need to diagnose.
The test results of this kit are for clinical reference only. It is recommended to conduct a comprehensive analysis of the condition based on the patient’s clinical manifestations and other laboratory tests.
Principle:
This kit uses one-step reverse transcription polymerase chain reaction (RT-PCR) detection technology to target the novel coronavirus (2019-nCoV) ORF1ab gene, N gene, and human internal reference gene sequence. Specific primers and taqman probes were designed in conserved regions.
Composition:
Composition |
48 tests / kit |
Reaction Mix A | 792μL×1Tube |
Reaction Mix B | 168μL×1Tube |
Positive Control | 50μL×1Tube |
Negative Control | 50μL ×1Tube |
Note: 1. Different batches of reagents should not be mixed.
2. Positive controls and positive controls need not be extracted
Test Procedure:
1. Nucleic acid extraction:
Commercial RNA extraction kits are available, magnetic bead extraction and spin column extraction are recommended for this kit.
2. Preparation the Reaction Mix:
● Take out the 2019-nCoV reaction Mix A/B and keep at room temperature until unfreezing;
● Take the corresponding portions (Reaction Mix A 16.5μL/T, Reaction Mix B 3.5μL/T) and mix, and then aliquot each PCR reaction with 20μL/ tube;
● Add 5μL of RNA template or negative control or positive control, then cover the tube cap;
● Place the reaction tube in the fluorescence PCR instrument, and set the negative / positive control and sample parameters for RT-PCR reaction according to the instrument operating instructions.
● Record Sample placement order
3.RT-PCR protocols:
Recommended Settings:
Cycle |
Time |
Temperature(℃) |
|
1 |
1 |
10min |
25 |
2 |
1 |
10min |
50 |
3 |
1 |
10min |
95 |
4 |
45 |
10s |
95 |
35s |
55 |
Product detail pictures:
Related Product Guide:
Our products are greatly acknowledged and reliable by users and may fulfill repeatedly shifting financial and social wants for Paint Drying Chamber Factory Quotes – Novel Coronavirus (2019-nCoV) Nucleic Acid Test Kit – INNOVITA , The product will supply to all over the world, such as: Mexico, Mexico, Estonia, we always keep our credit and mutual benefit to our client, insist our high quality service to moving our clients. always welcome the our friends and clients to come and visit our company and guid our business, if you are interested in our products, you can also submit your purchase information online, and we will contact you immediately, we keep our highly sincere cooperation and wish everything in your side are all well.
By John biddlestone from Eindhoven - 2017.06.29 18:55
It is a very good, very rare business partners, looking forward to the next more perfect cooperation!
By Elva from United Arab Emirates - 2017.01.28 18:53