banner

Products

Paint Drying Chamber Manufacturers Exporters – 2019-nCoV Ag Test (Latex Chromatography Assay) / Professional Test / Nasopharyngeal Swab – INNOVITA

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our purpose would be to offer good quality products at competitive price ranges, and top-notch support to clients around the whole world. We're ISO9001, CE, and GS certified and strictly adhere to their good quality specifications for Test Cassette, Urine Test Kit, Rapid Test PCR, Good quality would be the key factor to the company to stand out from other competitors. Seeing is Believing, want far more info? Just trial on its items!
Paint Drying Chamber Manufacturers Exporters – 2019-nCoV Ag Test (Latex Chromatography Assay) / Professional Test / Nasopharyngeal Swab – INNOVITA Detail:

Product Detail:

Innovita® 2019-nCoV Ag Test is intended for the direct and qualitative detection of SARS-CoV-2 nucleocapsid protein antigen in nasopharyngeal swabs from individuals who are suspected of COVID-19 by their healthcare provider within the first seven days of the onset of symptoms or for screening of individuals without symptoms or other reasons to suspect COVID-19 infection.
The test results of this kit are for clinical reference only. It is recommended to conduct a comprehensive analysis of the condition based on the patient’s clinical manifestations and other laboratory tests.

Principle:

The kit is a double antibody sandwich immunoassay based test. The test device consists of the specimen zone and the test zone. The specimen zone contains monoclonal antibody against the SARS-CoV-2 N protein and chicken IgY which both labeled with latex microspheres. The test line contains the other monoclonal antibody against SARS-CoV-2 N protein. The control line contains rabbit-anti-chicken IgY antibody.
After the specimen is applied in the specimen well of the device, antigen in the specimen forms an immune complex with the binding reagent in the specimen zone. Then the complex migrates to the test zone. The test line in the test zone contains antibody from a specific pathogen. If the concentration of the specific antigen in the specimen is higher than LoD, it will be captured at the test line (T) and form a red line. In contrast, if the concentration of the specific antigen is lower than LoD, it will not form a red line. The test also contains an internal control system. A red control line (C) should always appear after the test is completed. Absence of a red control line indicates an invalid result.

Composition:

Composition

Amount

IFU

1

Test cassette

1/25

Extraction diluent

1/25

Dropper tip

1/25

Swab

1/25

Test Procedure:

1.Specimen Collection
Place the swab into one of the patient’s nostrils until it reaches the posterior nasopharynx; keep inserting until resistance is encountered or the distance is equivalent to that from the ear to the nostril of the patient. The swab should be rotated on the nasopharyngeal mucosa for 5 times or more, and then taken out.

Nasopharygeal Swab (2)
2.Specimen Handling

Nasopharygeal Swab (4)

3.Test Procedure

Nasopharygeal Swab (1)

● Allow test device, specimen and diluent to equilibrate to room temperature 15~30℃ prior to opening the pouch. Remove the test device from the sealed aluminum foil pouch.
● Apply 3 drops of the test specimen into the specimen well.
● Wait for the red line(s) to appear at room temperature. Read results between 15~30 minutes. Do not read the result after 30 minutes.

Results Interpretation:

Nasopharygeal Swab (3)


Product detail pictures:

Paint Drying Chamber Manufacturers Exporters –  2019-nCoV Ag Test (Latex Chromatography Assay) / Professional Test / Nasopharyngeal Swab  – INNOVITA detail pictures

Paint Drying Chamber Manufacturers Exporters –  2019-nCoV Ag Test (Latex Chromatography Assay) / Professional Test / Nasopharyngeal Swab  – INNOVITA detail pictures


Related Product Guide:

We'll make each hard work to become excellent and excellent, and speed up our measures for standing from the rank of intercontinental top-grade and high-tech enterprises for Paint Drying Chamber Manufacturers Exporters – 2019-nCoV Ag Test (Latex Chromatography Assay) / Professional Test / Nasopharyngeal Swab – INNOVITA , The product will supply to all over the world, such as: Greenland, Venezuela, Southampton, Now, we professionally supplies customers with our main merchandise And our business is not only the "buy" and "sell", but also focus on more. We target to be your loyal supplier and long-term cooperator in China. Now, We hope to be the friends with you.
  • The company has a good reputation in this industry, and finally it tured out that choose them is a good choice.
    5 Stars By Jodie from Poland - 2017.12.31 14:53
    This supplier's raw material quality is stable and reliable, has always been in accordance with the requirements of our company to provide the goods that quality meet our requirements.
    5 Stars By Belinda from Somalia - 2018.09.23 17:37
    Write your message here and send it to us